Skip to content
POWER100
Content

Cheapest Good Mechanicals | Build Show Podcast Ep 218

📅 May 24, 2026 ⏱️ 49:25 🎤 Matt Risinger, Jordan Smith

Chapters

Click to jump to section

  • 0:00
    Intro & Build Show Live tease
  • 1:12
    Jeld-Wen windows & doors sponsor
  • 5:04
    Building mechanicals on a budget
  • 7:53
    Why zone dampers are garbage
  • 8:57
    Zones vs. separate equipment
  • 13:53
    Right-sizing & climate load
  • 18:45
    Brand reputation: Goodman & Daikin
  • 20:54
    The three-bid problem
  • 22:00
    One dehumidifier with fresh-air intake
  • 26:17
    The $400 dehumidification trick
  • 31:42
    Ductwork: flex vs. metal & commissioning
  • 39:48
    Ductless mini-split heads per room
  • 44:08
    Air quality & wrap-up

Speakers

M
Matt Risinger
Host
J
Jordan Smith
Builder, The Build Show

Key Takeaways

Zone dampers are a false economy — Matt and Jordan would skip them entirely and instead use separate pieces of equipment (mini-splits or multiple units) for each zone rather than choking a single system with dampers.

For an affordable-but-good HVAC system, right-sizing matters more than brand: a proper Manual J load calc and correctly matched equipment beats an oversized single-stage unit dumping air into rooms nobody uses.

Ductless and mini-split heads per room deliver high performance cheaply — installers were quoting roughly $1,000–$2,000 per room, so five heads can land around $10,000 total.

A single well-placed dehumidifier (Santa Fe, Aprilaire, etc.) with a fresh-air intake can handle humidity and ventilation for a whole house far more affordably than a full ERV plus separate dehumidification.

Brand reputation lags reality — Goodman is now built on the same line as Daikin (the 'Lexus' brand), so a bad experience a decade ago shouldn't rule out today's affordable equipment.

The three-bid, lowest-price HVAC selection process pressures contractors into cutting corners; a trusted relationship with one good installer produces a better-commissioned system.

On duct design, minimize metal and keep flex mainly on the return; if you use flex on supply, pre-stretch it and commission the system so long runs actually deliver their rated airflow.